Fechar

Access for registered users



Access to functionality

special site for

team, partners and customers.
Acesso Restrito

Training and Consulting in Medical Systems for Image Diagnostics

CT - Computed Tomography
Print E-mail

Computed Tomography - Basic Level



Hours:

- 5 days, 8 hours a day

Program content

 

Historical Aspects: Emergence of CT History and Development (CT Generations). Current news.
  • Methodology: the establishment and operation of a tomography (gantry, table, console, PDU, DAS, etc.).
  • Security: exhibit top security labels explaining their prominence. Electricity and patient.
  • Physical principles:
?    Matrix, pixel, voxel.
?    Hounsfield Unit Scale.
?    Detectors.
?    X-Ray Tube.
?    Kv, mA, automA.
?    Helical System (pitch, rotation, interpolation).
?    Multislice System (brief explanation).
  • Radiation Doses: Basic Theoretical Dosimetry Introduction. Radiation Care. Radiation Protection.
  • CT Artifacts and troubles: display the most common artifacts in CT spiral and troubles that may occur if the user does not follow the manufacturer's recommendations.
  • CT Workflow: A clinic operation since patient's arrival until results delivery.
  • Work Environment: Nursing, materials, remedies, documents, medical history and preparation.
  • Patient Positioning and Protocols: Demonstrate patient positioning and protocol arrangements. (Review).
  • Laboratory tests: Perform tests according to customer's needs. Exhibit View and Image Works tools.
  • Image Reconstruction:
?    Filters.
?    Algorithms for reconstruction.
?    Prospective and retrospective reconstruction.
?    3D: surface-rendered (Rendering Volume).
?    MIP, MinMIP, HDMIP.
?    MPR: multiplanar reconstruction (axial, sagittal, coronal, slanted and curved).
?    Navigator: air virtual navigation and contrast.
  • Photography and storage of images:
?    Photography of images on acetate film and / or paper.
?    Storage of images in DICOM, jpeg, mpeg, avi, etc. in MOD and / or DVD / CD.
 
Print E-mail

Computed Tomography - Advanced Level


Hours:

- 5 days, 8 hours a day MODULE 1: GENERAL

Program Content
  • ADVANTAGE WORKSTATION 4.2, 4.3 OR 4.4 (VOLUME VIEWER 3.0 OU 3.1):
?    General review of all Workstation start layout tools.
?    General review of all Viewer tools.
?    General review of all Volume Viewer tools: Reformat and Rendering Volume.
  • LUNG VCAR OR ALA:
?    Theoretical software presentation: What is VCAR? How to diagnose it? How to interpret it?
?    Laboratory tests and protocols setting.
?    Clinical applications: Study of clinical cases.
?    Practical applications: software application for review and analysis modes. Lung Vcar in single and multi applications.
?    Reporting Tool: (if applicable) to send the images and to edit pre-defined reports and the clinic logo.
?    Images archiving, paper printing and CD / DVD labeling.
  • ADVANTAGE CTC PLUS, PRO, PRO 3D OR COLON VCAR:
?    Theoretical presentation software: What is CTC? How to diagnose it? How to interpret it?
?    Patient preparation and materials needed.
?    Laboratory tests and protocols setting.
?    Clinical applications: Study of clinical cases.
?    Practical applications: software application for review and analysis modes. Applications in Colonography and CTC Auto and Virtual Dissection.
?    Reporting Tool: (if applicable) to send the images and to edit pre-defined reports and the clinic logo.
?    Images archiving, paper printing and CD / DVD labeling.

  • CT PERFUSION 2, 3 OR 4:
?    Theoretical software presentation: What is Infusion? How to diagnose it? How to interpret the maps?
?    Patient preparation and materials needed.
?    Laboratory tests and protocols setting: using software to scan shuttle mode (if applicable).
?    Clinical application: study of clinical cases.
?    Practical application: Brain Stroke, Brain Tumor, Body Tumor and Tissue Classification software (if applicable).
?    Images archiving, paper printing and CD / DVD labeling.

  • VESSELIQ XPRESS OR AVA:
?    Theoretical software presentation: What is analysis of vessels like? How to interpret it?
?    Patient preparation and materials needed.
?    Laboratory tests and protocols setting.
?    Clinical application: study of clinical cases.
?    Practical application: analysis of vessels software, MIP, lumen, analysis of stenosis, aneurysms and extraction of thrombus. Vessels measuring procedure before and after stents placement.
?    Reporting Tool: (if applicable) to send images and configure pre-defined reports and the clinic logo.
?    Images archiving, paper printing and CD / DVD labeling.

  • DENTASCAN:
?    Theoretical software presentation: What is Dentascan? How to interpret it?
?    Patient preparation and materials needed.
?    Laboratory tests and protocols setting.
?    Images calibration on film for appropriate measurements.
?    Practical application: software Dentascan, panoramic and slanted images.
?    Images archiving, paper printing and CD / DVD labeling.

  • BONE MINERAL DENSITOMETRY (BMD):
?    Theoretical software presentation: What is BMD? How to interpret it?
?    Laboratory tests and protocols setting.
?    BMD Phantom Calibration
?    Practical application: software QCT 5000TM Bone densitometry, densitometry and interpretation report doing.
?    Images archiving, paper printing and CD / DVD labeling..


MODULE 2: CARDIOLOGY

  • Security: to show how important the patient and these items are: cables position inside exam room, heart monitor, injection pump and patients. Demonstrate troubles that may occur if the user does not follow the manufacturer's recommendations.
  • Theoretical Application:
?    Cardiac physiology.
?    Cardiac anatomy, coronary arteries anatomy in CT images, cardiac veins anatomy.
?    Explanation of protocols: Segment Snapshot, Snapshot Burst, Snapshot Burst Plus and Snapshot Pulse (if applicable).
?    Explanation of Smartscore protocols and Timing Bolus.
?    Heart monitor and EKG.
?    Work environment: nursing, materials, remedies, documents, medical history and preparation.
?    Laboratory tests and protocols setting.
  • Software applications:
  • SMARTSCORE 3.5 OR 4.0:
?    Theoretical software presentation: What is Smartscore? How to interpret it?
?    Volume Measurement (mm3), Agatston (AJ130) and mass (mg) (if applicable).
?    Report of the calcium score, printing and images archiving on CD / DVD.
  • CARDIQ XPRESS 2.0 PLUS, PRO OR ELITE:
?    Practical applications on images reconstruction in rendering volume.
?    Analysis of vessels on every coronary artery.
?    Measurement of stenosis and application of vessel coloring according to each density.
?    Registration of stages.
?    2D Cardiac Display.
?    Slanted and curved MIP images.
?    Movements of heart chambers video performances (heart reformatting).
  • CARD FUNCTION OR XPRESS FUNCTION:
?    Left and right ventricle ejection fraction.
?    Left and right atrium ejection fraction (if applicable).
?    Calculation of systolic and diastolic volumes.
?    Measurement of cardiac output (ml / min) (if applicable).
?    Analysis of the myocardium: parietal thickness, parietal movement.
?    Relative myocardial perfusion (if applicable).
  • CARDEP:
?    Images reconstruction in Rendering Volume of the left atrium.
?    Analysis and reformatting of pulmonary veins.
?    Analysis of left atrial appendage.
?    Virtual navigation of the pulmonary veins.
?    Analysis of coronary sinus.


 
More Articles...
<< Start < Prev 1 2 Next > End >>

Page 1 of 2

Browsers

This site is best viewed
with the browsers below.
Click to download the latest version.

firefox_88x31ie7

Customer Care

(11) 2092-4345

Rua Tuiuti, 2.530 - CJ 12/13 Tatuapé
São Paulo - SP - CEP: 03307-000
atendimento@alsoimagem.com.br